Hi-tech cubic commercial air coolers for A2L refrigerants
Efficient cooling made simple

Vantage SFHC

Compact commercial unit coolers designed for safe use of A2L refrigerant and for optimal conservation of fresh and frozen goods in commercial refrigeration.

Consultant

Vantage SFHC provides safety compliance and advanced coil technology for projects adopting low-GWP A2L refrigerants. Eurovent certified performance for verified performance and comprehensive technical documentation for accurate system calculations and compliant design choices in line with the latest F-Gas and regulatory requirements. Multiple fin spacing and defrost options for optimized design flexibility.

Not your profile?

What profile fits you best?

Let's know each other better

Not sure which applies to you? Contact us for personalized guidance.

Select your Application

Which sector/application are you interested in?

Select your application to discover tailored features and benefits

Refrigeration
  • High-efficiency EC fans as standard.
  • High-efficiency coils with TURBOFIN aluminum fins for superior heat transfer.
  • Available with insulated suction hood for optimized air distribution.
  • Easy maintenance and cleaning with dismountable and openable casing.
  • High capacity and long air throw, thanks to patented Jetstreamer grill.

Technical Highlights

  • Designed for safe use of ASHRAE A2L refrigerants, suitable for A1 refrigerants.
    Discover our CO2/brine refrigerants dedicated series
  • Modular commercial air cooler in draw-through design.
  • Cooling capacity (SC2): from 1.45 kW up to 27.5 kW
  • Internally grooved copper tubes, with TURBOFIN aluminium fins. Multiple fin spacing options (4.5 up to 9 mm).
  • EC fan motors with 275, 315 and 350 mm diameter, 1 to 4 fans per unit. Single speed fans for F27 models, dual speed or 0-10 V control input for F31 and F35 models.
  • Corrosion resistant galvanized steel casing, epoxy-coated RAL 9003.
  • Electric defrost available for A2L refrigerants listed in IEC standard 60335- 2-40
  • Designed for high energy efficiency and low defrost frequency.
  • Eurovent certified for verified performance and reliability.
    Download Eurovent certificate or Learn more about Eurovent
  • Configure your ideal solution quickly with our online selection software: Plair – Start your tailored configuration

Plair — Cold Room Calc

 

Plair is LUVE’s collaborative selection tool for air heat exchangers, designed to simplify configuration and speed up quotation processes.
Our Cold Room Calculator helps you define the correct heat load for cooling and freezing rooms.

Distinctive Technologies

TURBOCOIL heat exchanger

Unique to LUVE, ensures maximum performance and minimized defrost frequency.

Discover TURBOCOIL TECHNOLOGIES

Jestreamer

Directional grill ensures uniform airflow through the coil, increasing air quantity even with frosted coils.

High efficiency fan motors

State-of-the-art EC fan motors deliver optimum airflow with low energy consumption and compliance with ErP energy efficiency standards

Top Advantages

A2L safety compliant

Designed for safe and reliable use with environmentally friendly A2L refrigerants, including electric defrost for refrigerants included in IEC standard 60335- 2-40

Reliable performance, Eurovent certified, independently tested
Extremely low internal volume

Reducing refrigerant charge

Reliable, quiet and energy efficient
Easy-access, easy-clean

Fully accessible casing

Technical features

  • Main applications
    SFHC is the range of commercial unit coolers from LUVE, designed for safe use of ASHRAE A2L refrigerant and for optimal conservation of fresh and frozen goods in commercial refrigeration.
  • Refrigerant
    A1, A2L
  • Capacity range
    1.45 up to 27.5 kW
  • Air quantity
    900 up to 10,400 m3/h
  • Fan-motors
    1 to 4 fans fitted with high-efficiency EC fan motors
  • Fan diameters
    ø 275, 315 and 350 mm

 

Refrigerant
A1, A2l
Capacity range
1.45 up to 27.5 kW
Air quantity
900 up to 10,400 m3/h

Casing

  • Corrosion-resistant galvanized steel casing with epoxypolyester powder coating RAL 9003.

Fan-Motors

  • 1 to 4 fans fitted with high-efficiency EC fan motors with incorporated thermal protection.
  • Available in 3 fan diameters (275, 315 and 350 mm) drawing through the coil.
  • Dual speed or 0-10V control input motors for F31 and F35 models.
  • Power supply 230/1/50-60.

Options

  • Electric defrost in coil (E).Certified for the use of the only A2L refrigerants listed on the IEC standard 60335-2-40 (R-32, R-1234YF, R-1234ZE (E), R-444A, R-444B, R-447B, R-451A, R-451B, R-452B, R-454A, R-454B, R-454C, R-455A)
  • Electric defrost in driptray (DTH)
  • Electric defrost in coil + driptray (E+DTH)
  • Fan shroud heater.
  • Coil corrosion protection: Alupaint (AP).
  • EC fan motors: single speed for F27, dual speed or 0–10 V control input (0-10) for F31 and F35.
  • EC fan motor with 0–10 V control input (0-10) – for F35 models
  • EC fan motor with 0–10 V control input + potentiometer (0-10P) – for F35 models
  • Driptray insulation.
  • Shut-up sock with adapter ring – for F31 and F35 models
  • Insulated suction hood for F31 and F35 modeld

JET STREAMER®

  • LUVE patented the JETSTREAMER® directional grill.
  • The innovative design of its profile provides:
    • Uniform distribution of airflow through the coil.
    • Significant increase in air quantity, both with frostfree coil (+4 to +9%) and with frost on the coil (+7 to +15%).
  • The improvement in air quantity during the frosting stage guarantees superior capacity and +25% air throw.

Coil

  • The very high-efficiency TURBOCOIL® heat exchangers have the best power/cost ratio obtainable.
  • High-efficiency TURBOFIN® aluminum fins with special configuration of the louvre profile to reduce dehumidification and frost formation.
  • High-efficiency small-diameter copper tubes with internal helical grooving, designed for optimal evaporation of the new refrigerant fluids.
  • Standard fin spacings 4.5, 6 and 7 mm.

Design Pressure

  • Design pressure 24 bar.
  • Each heat exchanger is leak tested with dry air and finally supplied with a dry air pre-charge.

Certifications

  • The LUVE quality system is in accordance with ISO 9001. All products are manufactured according to PED regulations. LUVE participates in the ECP program for HE.
    Check ongoing validity of certificate: www.eurovent-certification.com

Download

Vantage SFHC for A2L applicationsLeafletENGLISH Download
Air CoolersProduct manual
Download
Vantage SFHC - SF27HCInstruction manualENGLISH|FRENCH|GERMAN|ITALIAN|RUSSIAN|SPANISH Download
Vantage SFHC - SF31HC | SF35HCInstruction manualENGLISH|FRENCH|GERMAN|ITALIAN|RUSSIAN|SPANISH Download
Vantage SFHC - SF31HC | SF35HCPictureImage 1 Download

Fin Patterns